MSDS
Technique
MicroPrimeoPrime
Material Safety Data Sheet
SECTION I - PRODUCT IDENTIFICATION MSDS NO. ROOS
Company: Danville Materials
2021 Omega Road
San Ramon, CA 94583
Phone: (800) 822-9294
Fax: (925) 838-0944
Prepared: April 10, 1997
SECTION II - HAZARDOUS INGREDIENTS OF MIXTURES
Material % WGT OSHA PEL ACGIH TLV
Benzethonium Chloride 1-5% .2 ppmv 0.2 ppmv
Hydroxylethyl Methacrylate 25-45 N/A NA
Sodium Fluoride 10 ppm N/A N/A
Water Balance
(ND = Not Determined NA = Not Applicable NL = Not Listed)
SECTION III - PHYSICAL DATA
Vapor Pressure mm HG: NA
Evaporation Rate (Ether = 1): NA
Solubility in Water: Soluble
Appearance: Clear Liquid
SECTION IV - FIRE AND EXPLOSION
Flash Point: >+104OC
Extinguishing Media: Carbon Dioxide, Foam, Dry Chemical
Special Fire Fighting Procedures: None
Flammable Limits: NA
Unusual Fire and Explosion Hazards: None
SECTION V - REACTIVITY DATA
Stability: Stable
Conditions to Avoid: Prolonged Extreme Heat.
Incompatibility: (Materials to avoid) Contact with iron.
Hazardous Decomposition Products: None.
Hazardous Polymerization: None
Conditions to Avoid: Extreme heat and free radical initiators.
SECTION VI - HEALTH HAZARDS
OSHA Permissible Exposure Limits: None
Other Exposure Limit Used: None
ACGIH Threshold Exposure Limit: None
Chronic, Other: None
Acute Overexposure: Irritation to eyes and skin. May cause chemical
burn.
Medical Conditions Generally Aggravated by Exposure: None Known
Hygienic Practices: None
Primary Route(s) of Exposure: Skin, eye, ingestion.
SECTION VII - EMERGENCY AND FIRST AID PROCEDURES
Skin: Wash off affected area with soap and water.
Ingestion: Seek immediate medical advice, carry container with label.
Eyes: Rinse immediately with plenty of water and seek medical advice.
SECTION VIII - SPILL OR LEAK PROCEDURES
Spill Management: Use absorbent to collect the material. Wash contaminated
surfaces with soap and water.
Waste Disposal Methods: Dispose of safely in accordance with local,
state and federal regulations.
SECTION IX - PROTECTION INFORMATION/CONTROL MEASURES
Respiratory: None required Eye Protection: Safety goggles
Glove: Rubber/PVC gloves Other Clothing & Equipment: None
Ventilation: None required
SECTION X - ADDITIONAL INFORMATION
Acute Toxicity: ID oral rat. 2,000 mg/kg
Ames Test: Negative. Acrylates can cause sensitization reactions.
Disclaimer: Techniques, Tips and MSDS are presented as
a service by Sure / Dental Innovations
and are presented as suggestions only. In all cases offices are asked
to consult manufacturers current Instruction Sheets and MSDS.
Sure / Dental Innovations is not liable for information presented at
this site.
|